Reference · Coating tests
Salt spray test (ASTM B117) for coated aluminum.
A salt spray test exposes coated panels to a continuous salt fog in a closed cabinet, then inspects them for corrosion and paint damage. ASTM B117 defines how that cabinet is run. It does not define the panels, the exposure time or what counts as a pass, and its hours do not convert into years of service. This page explains what the test shows on coated aluminum and how to read the hours on a datasheet.
- Accelerated laboratory exposure
- Scribed, coated panels
- Comparative, not predictive
What is a salt spray test?
A salt spray test, also called a salt fog test, is an accelerated corrosion exposure. Test panels sit in a sealed cabinet while a salt solution is atomized into a fine fog that settles on them for the whole test. At set intervals, or at the end of an agreed number of hours, the panels are taken out and inspected. It is used to compare coating systems, pretreatments and production batches under the same harsh, repeatable conditions.
The test is simple, repeatable and inexpensive compared with years of outdoor exposure. Its limits come from the same simplicity: a constant wet salt fog is not what a roof, a facade or a shutter sees outdoors, where wetting and drying, sunlight, temperature swings and pollutants all change over a day and a season.
What does ASTM B117 actually specify?
ASTM B117 is titled "Standard Practice for Operating Salt Spray (Fog) Apparatus". The current edition is ASTM B117-26a; ASTM revises it periodically, so check the edition on the ASTM store. As the title says, it is a practice for running the equipment. It covers the apparatus, the procedure and the conditions needed to create and maintain the salt fog environment, so that cabinet conditions are defined, although results can still vary between cabinets and laboratories.
Just as important is what B117 leaves out. It does not prescribe:
- The type of specimen, or how it is prepared.
- How long the specimens are exposed.
- How the results are interpreted, or what counts as a pass.
Those choices come from the product or coating specification that calls up B117, or from an agreement between buyer and seller. A report that says only "tested to ASTM B117" tells you only that the cabinet was stated to be run to B117. It does not tell you how the panels were made, how long they ran, or how they were judged.
How are coated aluminum panels prepared and assessed?
For coil coated aluminum, test panels are usually cut from production or trial coil, so they carry the real pretreatment, primer and topcoat. Where the specification calls for it, a scribe is cut through the paint film before exposure down to the metal, deliberately creating a defect. The scribe imitates the scratch or cut a panel gets during fabrication and installation, and it is where corrosion under the paint starts.
After exposure, the panels are rinsed and examined. The usual observations are:
| Observation | What it describes | What it tells you |
|---|---|---|
| Creep from scribe | How far corrosion or loss of adhesion has spread under the paint, measured away from the scribe line | How well the pretreatment and primer hold the film to the metal once it is damaged |
| Blistering | Size and density of blisters in the film, on the scribe and on the open face | Moisture and salt getting through or under the film |
| Face condition | Corrosion, staining or film damage away from the scribe | Whether the intact film itself is holding up |
Creep and blistering are rated against the method and rating scale named in the coating specification. ASTM D1654 covers evaluating painted or coated specimens after corrosion exposure, including loss of adhesion at a scribe mark. ASTM D714 rates blister size and density with photographic reference standards, and buyer and seller agree the permissible level. Two labs using different rating scales or different scribe tools can rate the same panel differently, which is why the assessment method matters as much as the hours.
What salt spray results mean, and what they do not
ASTM itself cautions that results from salt spray testing, used as stand-alone data, have seldom been correlated with how a material performs in natural environments. In plain terms: a salt spray result is not a forecast of service life.
What a result can do is rank. When two coating systems, two pretreatments or two production lots run in the same cabinet, on panels prepared the same way and judged the same way, the one with less creep and blistering ranks higher in that test, though the ranking does not always hold in outdoor exposure. That makes it useful for quality control and screening.
What a result cannot do is tell you how many years a coating will last on a building, or compare a coating tested in one program with another coating tested somewhere else under different rules.
How salt spray hours appear on paint datasheets
Coating and coil coating datasheets often list a salt spray figure as a number of hours, sometimes with a rating attached. Read it with these checks:
- Same method. Both figures should come from B117, or both from the same other method. Hours from different tests are not comparable.
- Same panel preparation. Substrate, pretreatment, film build and scribe all change the result. A figure on a thick film over steel says little about a thin film over aluminum.
- Same assessment. Check what was measured at the end and against which scale, and whether the figure is a pass at those hours or simply the hours the test ran.
- Hours are not years. There is no conversion factor from cabinet hours to outdoor service, and a datasheet that implies one is going further than the test supports.
If a datasheet does not state all of this, ask for the test report. For Orbit's coating systems on prepainted aluminum coil, test reports for a given system and color are available on request; state both with your RFQ.
Related corrosion tests
Because continuous salt fog is a narrow model of the outdoors, coating specifications often add or substitute other exposures:
- Cyclic corrosion tests such as ASTM G85 annex A5 and ISO 16701 alternate salt exposure with dry or changing-humidity phases. Their wet and dry changes are generally regarded as closer to outdoor conditions than a constant fog.
- Outdoor exposure puts panels on racks at real sites, often coastal or industrial ones. It is slow, but it measures the conditions a building actually meets, and some architectural coating specifications include it.
- Filiform tests look for thread-like corrosion growing under the paint from a defect, a form of attack that matters on coated aluminum. EN ISO 4623-2 is the method for aluminum substrates and uses scribed coated panels. The filiform corrosion reference explains how it forms and how pretreatment affects it.
For how bare and coated aluminum corrode in different environments, and what galvanic contact with other metals does, see the guide to how aluminum corrodes.
Standards referenced
- ASTM B117, Standard Practice for Operating Salt Spray (Fog) Apparatus
- ASTM D1654, evaluation of painted or coated specimens subjected to corrosive environments, including scribe creep
- ASTM D714, evaluating degree of blistering of paints
- ASTM G85 annex A5 and ISO 16701, cyclic corrosion tests
- EN ISO 4623-2, Paints and varnishes. Determination of resistance to filiform corrosion. Part 2: Aluminium substrates
Salt spray questions.
What is ASTM B117?
ASTM B117 is the Standard Practice for Operating Salt Spray (Fog) Apparatus. It covers the apparatus, procedure and conditions for creating and maintaining a salt fog environment. It does not set the specimen type, the exposure time or how results are interpreted.
How many salt spray hours equal one year outdoors?
There is no conversion. ASTM notes that salt spray results used on their own have seldom been correlated with performance in natural environments, so hours in the cabinet cannot be turned into years of service.
Does ASTM B117 define a pass or fail?
No. The pass criteria, exposure time and panel preparation come from the product or coating specification that calls up B117, or from an agreement between buyer and seller.
Why are test panels scribed?
The scribe cuts through the coating to the metal, imitating fabrication or installation damage. Measuring how far corrosion creeps from the scribe shows how well the pretreatment and primer hold the paint once the film is broken.
Can I compare salt spray hours from two different datasheets?
Only if both used the same method, the same panel preparation and the same assessment. If a datasheet does not state these, ask for the test report before comparing.
Can Orbit provide salt spray results for its coatings?
Test reports for a given system and color are available on request; state both with your RFQ.
Need test data for a coating system?
Send the coating system, color, alloy, thickness, width, quantity and destination, and say which test reports you need. We respond to RFQs within one business day.