Standing Seam Aluminum Roof: Specifying the Coil.
A standing seam aluminum roof is only as good as the coil it is roll formed from. Roll formers specify alloy, temper, thickness, width, flatness, coating, color and protective film, and each one affects how the panel forms, seams, looks and moves on the roof.
Key takeaways
- The panel system sets most of the coil specification: thickness, width and the forming the seam needs.
- Temper has to suit seaming. Harder tempers give a stronger pan that resists denting better, but they spring back more and can crack in a tight fold; softer tempers seam more easily.
- Flatness matters on wide, flat pans, where waviness shows.
- Coating system, color, gloss and protective film are part of the coil order, not details for later.
- Aluminum expands and contracts with temperature, so the roof system has to let long panels move.
What does a standing seam aluminum roof need from the coil?
Coil that forms the profile cleanly, closes the seam without cracking the metal or the paint, and lies flat on the roof. In a standing seam system, long metal pans run from ridge to eave and join along raised seams, usually with concealed clips that hold the panels to the deck. The roll former turns flat coil into those pans on site or in the shop.
Most of the coil specification comes from the panel system: its design fixes the thickness, the coil width and how severe the seam fold is. The roll former's job is to buy coil that matches it. The points below are what a roll former typically writes on the order.
Which alloy series is used for roofing coil?
Non-heat-treatable alloys from the 3xxx and 5xxx series are both used for roofing coil. 3xxx alloys, alloyed with manganese, offer a balance of formability and moderate strength. 5xxx alloys, alloyed with magnesium, are stronger and usually need more generous bends at a comparable temper. The panel system maker or the project specification usually names the alloy.
Orbit rolls 1xxx, 3xxx and 5xxx alloys, and 3105 is its main coated substrate. The page on aluminum roof coil sets out the alloys and coatings Orbit supplies for roofing.
Why does temper matter for seaming?
A standing seam is folded, and in mechanically seamed systems it is folded again, so the metal at the seam takes the tightest bend on the panel. Harder tempers give a stronger pan that resists denting better, but they spring back more and can crack in a tight fold. Softer tempers seam more easily but resist denting less.
On coated coil, the paint film has to survive the fold as well. Ask for the coating's T-bend result, and state the temper on the order or describe the seam so the supplier can propose one.
How is thickness chosen?
By the panel system and the project's structural design, not by the coil supplier. Span between supports, wind exposure and the seam design all feed into it. Thickness on a roofing order should be stated in millimeters or inches, because gauge numbers mean different thicknesses for different metals. The sheet metal gauge chart converts gauge to thickness if a drawing uses gauge.
Orbit's coated coil is available up to 1.60 mm thick. The exact thickness for a roofing profile is confirmed against the panel system's requirement.
How wide should the coil be?
As wide as the roll former's profile needs, which is the developed, flat width of the panel. A coil that is too wide wastes metal; one that is too narrow will not form the full profile. Width tolerance matters too, because the seam legs at both edges depend on it.
The post on choosing coil width for a roll-formed profile works through the calculation. Orbit supplies coated coil up to 1350 mm wide, and slitting is one of its in-house capabilities.
Why does flatness matter on wide pans?
The flat pan between seams is a wide, lightly supported area, and it shows waviness, often called oil canning, more than a ribbed profile does. Oil canning has several causes, including installation, substrate and thermal movement, but coil shape is one of them: edge wave, center buckle or uneven stress across the strip can carry through into the panel.
Dimensional tolerances for aluminum sheet are set in ANSI H35.2 in US practice, and tolerances on shape and dimensions for cold-rolled products in EN 485-4 in Europe. If the roof has wide, flat pans, state the flatness requirement on the order rather than relying on the default.
Which coating, color and film should the order state?
- Coating system. Chosen for the exposure and the color retention the project needs. PVDF coated aluminum is specified where long-term resistance to chalking and color loss is the priority; other systems can suit milder exposures.
- Color and gloss. A RAL number or a physical sample, plus a gloss level and an agreed color tolerance.
- Reverse side. The back of the panel faces the deck or underlay, so state what coating it needs.
- Protective film. A strippable film protects the coated face during roll forming, handling and installation. Agree the film type with the supplier and follow its guidance on how long the film may stay on, especially in sunlight.
Orbit's coating systems are PE, HDPE, PVDF, PU, PUPA, Epoxy, Acrylic and Epoxy-PE, in RAL or custom colors. Coil coated sheet for general applications in Europe is specified under EN 1396.
How does thermal movement affect the specification?
Aluminum expands and contracts with temperature, and more than steel does for the same temperature change. On a long roof panel that movement adds up, which is why standing seam systems use clips that let the panels slide along their length instead of fixing them rigidly at every support. The coil supplier does not design this, but it is a reason to keep the panel system's own fixing details with the coil specification.
Common questions
What alloy is used for a standing seam aluminum roof?
Non-heat-treatable 3xxx and 5xxx alloys are both used. The panel system or project specification usually names the alloy and temper.
Who decides the thickness of standing seam panels?
The panel system and the project's structural design, based on span, wind exposure and seam design. The coil order then states that thickness in millimeters or inches.
Why do standing seam panels show waviness?
Waviness, or oil canning, has several causes, including installation and thermal movement. Coil flatness is one of them, so state a flatness requirement for wide, flat pans.
Should standing seam coil come with protective film?
A strippable film protects the coated face during forming and installation. Agree the film type with the supplier and follow its guidance on removal, especially in sunlight.
Does aluminum roofing move with temperature?
Yes. Aluminum expands and contracts with temperature, more than steel does, so standing seam systems use clips that let long panels move along their length.
References
- ANSI H35.2, Dimensional Tolerances for Aluminum Mill Products.
- CEN: EN 485-4, Sheet, strip and plate. Tolerances on shape and dimensions for cold-rolled products.
- CEN: EN 1396, Coil coated sheet and strip for general applications. Specifications.
- Orbit Aluminum Industries: roofing application page, for the alloys and coating systems supplied for roofing.
Roll forming a standing seam profile?
Send the alloy, temper, thickness, coil width, coating system, color and quantity. We respond to RFQs within one business day.